Decrease HVAC equipment sizes and cut energy usage by reducing outdoor air intake in accordance with ASHRAE’s Standard 62.1 IAQ Procedure.
By utilizing the ASHRAE 62.1 IAQ Procedure (IAQP) combined with Plasma Air technology, consulting engineers can deliver optimal indoor air quality, significant first cost savings and reduction in ongoing energy usage to their clients by reducing outside air intake by up to 75%. Plasma Air takes the time and guesswork out of using the IAQP for new construction and retrofit projects by providing the necessary documentation and free access to PlasmaSoft – our award-winning software for making IAQ calculations and generating the associated specifications.
High density buildings are ideal candidates for the ASHRAE IAQ Procedure. Plasma Air equipment is easily installed in the supply air ductwork or in the air handler itself so no special provisions are required. The ionizers use only a few watts of power and there is no discernible pressure drop to worry about. In addition to the ASHRAE IAQ Procedure calculations, we also provide project specifications, ionization schedules, CAD drawings and our in-house engineering support by contacting us or your nearest Plasma Air distributor.
Before PlasmaSoft IAQP Software, we were unable to perform Indoor Air Quality Procedure (IAQP) calculations, meaning many of our customers were forced to rely on the expensive Ventilation Rate Method. This resulted in building owners and operators using more outdoor air than necessary in an attempt to maintain ASHRAE compliance. PlasmaSoft provides a turnkey, easy-to-use solution for the execution of complex calculations required by the IAQP.
-John Bruno
Atlas Design & Engineering, Fort Myers, FL
VRF units have a limited ability to process outside air; they are just not designed to handle a great deal of outside ventilation air, as required by code. This is where the Plasma Air solution comes in. What Plasma Air allows you to do is reduce the amount of outside air whilemaintaining acceptable indoor air quality.
-Thomas Pisarek, Owner
Pisarek Engineering, New Jersey
I've designed dozens of schools and churches utilizing Plasma Air's system to meet the requirements of ASHRAE's IAQ Procedure. In addition to positive feedback on the air quality, we saved our clients millions of dollars in construction costs and ongoing energy savings.
-Chief Mechanical Engineer
BGW Services, Inc.
PlasmaSoft IAQ Procedure Software is the first web-based program of its kind enabling calculations required in ASHRAE’s Standard 62.1 IAQ Procedure. The program calculates and compares contaminant levels using both ASHRAE’s Ventilation Rate Method (VRM) and the Indoor Air Quality Procedure (IAQP) in reducing outside air intake.
Learn more about Plasma Air, the IAQ Procedure, and get access to PlasmaSoft – our award-winning IAQ Procedure Software
Get news and updates about our latest products and offerings